Soft Starter New

Soft starter 162A 90kWith400V 110kWith600V US=100-240V AC bypass ADXL0162600 /T2UK


Soft starter 162A 90kWith400V 110kWith600V US=100-240V AC bypass ADXL0162600 /T2UK

Soft starter 162A 90kWith400V 110kWith600V US=100-240V AC bypass ADXL0162600 /T2UK   Soft starter 162A 90kWith400V 110kWith600V US=100-240V AC bypass ADXL0162600 /T2UK
Soft starter 162A 90kW/400V 110kW/600V US=100-240V AC bypass ADXL0162600 /T2UK. PKWiU: 27.90.41.0. Type of control voltage: AC. Rated control voltage Us for AC 50 Hz [V] from: 100. Rated control voltage Us for AC 50 Hz [V] up to: 240.

Rated control voltage Us for AC 60 Hz [V] from: 100. Rated control voltage Us for AC 60 Hz [V] up to: 240.

Rated operating voltage Ue [V]: 400. Rated operating current Ie at 40 °C Tu [A]: 162. Rated power of a three-phase motor, standard connection, at 400 V [kW]: 90.

Rated ambient temperature without reduction [°C]: 40. Application types: · General (GP) · Centrifugal pump · Fire pump · Conveyor belt · Fan · Agitator Basic parameters. For standard and heavy loads. Rated current of the soft starter Ie: 162A.

Motor current regulation from 50 to 100% of the soft starter's rated current. Input voltage range: 208...600VAC.

Rated motor power 90kW (400VAC). Soft starters with starting voltage reduction, torque control.

Limitation of maximum starting current. Built-in softstarter and motor protection. LED indicators to indicate the status of the soft starter.

Optical port for programming, data download and diagnostics. NFC communication for programming parameters. Modbus-ASCII, Modbus-RTU and Modbus-TCP communication protocols.

Backlit LCD display with icons. Description · Backlit LCD display with icons.

· 3 LED indicators to indicate operating status (power, ramp/run, failure). · Texts of measurements, settings and messages in 6 languages (EN-IT-FR-ES-PD).

· Front panel keyboard with 4 buttons for setting all parameters. · AUTOSET application wizard for quick setup, in 4 steps, of typical applications (pumps, fire pumps, belt conveyors, mixers, fans, general use).

· 2-phase control, built-in bypass relay. · 4 different mechanical sizes and 11 electrical ranges: for motors from 30 to 320 A rated current. · Voltage or torque ramp starting, taking into account the maximum starting current limitation. · Fan with thermostat (option in ADXL30.115), with dedicated diagnostics (fan disconnected or blocked).

· 3 programmable digital inputs, including one that can be configured for protection via a PTC sensor. · 3 programmable relay-type digital outputs, including one switchable (C/O) and two normally open (NO). · Separated auxiliary power supply.

· Built-in electronic thermal protection, multi-class, separate for startup and operation. · Complete set of motor protections: phase loss, missing power line, phase sequence, phase unbalance, rotor stall, dry running (minimum torque), too long starting time, too high or too low voltage.

· Analog temperature sensor for thyristor protection, with display indications and alarm and pre-alarm thresholds. · NFC interface for programming using a smartphone. · Front optical interface for performing programming and maintenance.

· Isolated optional RS485 interface, connection in a dedicated socket with Modbus protocols. · Alarms with user-programmable language text and properties. · Compatible with SAM1 app, NFC configurator app, Synergy supervision software and Xpress configuration and remote control software. · Optional accessories for DIN rail mounting (for ADXL 30.115). · Optional cabinet door display to control multiple startup devices.