Insulation voltage rated value V 690. Pollution degree 3, according to IEC 60947-4-2.
Reference mark in accordance with din EN 61346-2 Q. Reference designation according to din 40719 extended according to IEC 204-2 according to IEC 750 G. At 40 ° C rated value A 47. At 50 ° C rated value A 42. At 60 ° C rated value A 37.
Operating current for three-phase motor with inside-delta circuit. At 40 ° C rated value A 81. At 50 ° C rated value A 73.
At 60 ° C rated value A 6. Mechanical power output for three-phase motor. With standard circuit at 40 ° C rated value W 22 000.
With inside-delta circuit at 40 ° C rated value W 45 000. With standard circuit at 40 ° C rated value W 30,000. At 690 V with standard circuit at 40 ° C rated value W 45 000. Operating frequency, rated value Hz 50... Relative negative tolerance of the operating frequency% -10.Relative positive tolerance of the operating frequency% 10. Operating voltage with standard circuit rated value V 400... Relative negative tolerance of the operating voltage with standard circuit% -15.
Relative positive tolerance of the operating voltage with standard circuit% 10. Operating voltage with inside-delta circuit, rated value V 400... Relative negative tolerance of the operating voltage with inside-delta connection% -15. Relative positive tolerance of the operating voltage with inside-delta connection% 10 minimum load [%]% 8. Adjustable motor current for motor overload protection minimum nominal value A 9 Continuous operating current [% of Ie] at 40 ° C% 115 Power loss [W] at operating current at 40 ° C during operation typically W 32.
With over 1000 articles online and a constantly growing product portfolio, our goal is to provide you with every part you need as quickly as possible. Reference designation according to din 40719 extended according to IEC 204-2 according to IEC 750 G relative negative tolerance of the operating voltage with standard circuit% -15 Relative positive tolerance of the operating voltage with standard circuit% 10 Relative negative tolerance of the operating voltage with inside-delta connection% -15 Relative positive tolerance of the operating voltage with inside-delta connection% 10 minimum load [%]% 8 Adjustable motor current for motor overload protection minimum nominal value A 9 Continuous operating current [% of Ie] at 40 ° C% 115 Power loss [W] at operating current at 40 ° C during operation typically W 32 With over 1000 articles online and a constantly growing product portfolio, our goal is to provide you with every part you need as quick. This item is in the category "Business, Office & Industrial\Industrial Automation & Motion Controls\Drives & Starters\Starters\Reduced Voltage/Soft Starters". The seller is "industrie24" and is located in this country: DE. This item can be shipped worldwide.