SOFT STARTER FOR ASYNCHRONOUS MOTOR ATS01 22A 460-480V. 460...480 V - 10...10 %. 10 hp 3 phases 460...480 V.
15 hp 3 phases 460...480 V. 110 A at nominal load. 124.5 W in transient state. 4.5 W at full load and at end of starting. 50...60 Hz - 5...5 %.Adjustable from 1 to 10 s. 30...80 % of starting torque of motor connected directly on the line supply. Logic LI1, LI2, BOOST stop, run and boost on start-up functions. 13 V >= 0.5 mA. Open collector logic LO1 end of starting signal.
Relay outputs R1A, R1C NO. 24 V 6...30 V open collector logic. 10 mA 6 V DC relay outputs. 2 A 250 V AC inductive cos phi = 0.5 20 ms relay outputs.
2 A 30 V DC inductive cos phi = 0.5 20 ms relay outputs. 1 LED green starter powered up. 1 LED yellow nominal voltage reached.1.9...2.5 N. 4 mm screw clamp terminal rigid 1 1...10 mm² AWG 8 power circuit.
Screw connector rigid 1 0.5...2.5 mm² AWG 14 control circuit. 4 mm screw clamp terminal rigid 2 1...6 mm² AWG 10 power circuit. Screw connector rigid 2 0.5...1 mm² AWG 17 control circuit. Screw connector flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit. 4 mm screw clamp terminal flexible without cable end 1 1.5...10 mm² AWG 8 power circuit.
Screw connector flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit. 4 mm screw clamp terminal flexible with cable end 2 1...6 mm² AWG 10 power circuit. 4 mm screw clamp terminal flexible without cable end 2 1.5...6 mm² AWG 10 power circuit. Screw connector flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit.
Damped oscillating waves level 3 IEC 61000-4-12. Electrostatic discharge level 3 IEC 61000-4-2. Immunity to electrical transients level 4 IEC 61000-4-4. Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3. Voltage/current impulse level 3 IEC 61000-4-5. Conducted and radiated emissions level B CISPR 11. Conducted and radiated emissions level B IEC 60947-4-2. Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6. Micro-cuts and voltage fluctuation IEC 61000-4-11. B44.1-96/ASME A17.5 for starter wired to the motor delta terminal.1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6. 1 gn 13...150 Hz EN/IEC 60068-2-6. 15 gn 11 ms EN/IEC 60068-2-27.
5...95 % without condensation or dripping water EN/IEC 60068-2-3. Ambient air temperature for operation. 10...40 °C without derating. 40...50 °C with current derating of 2 % per °C.Ambient air temperature for storage. 25...70 °C EN/IEC 60947-4-2. > 1000 m with current derating of 2.2 % per additional 100 m.
WE CAN COMBINE YOUR SHIPPIN. The item "SCHNEIDER ELECTRIC ATS01N222RT SOFT STARTER FOR MOTOR ATS01 22A 460-480V" is in sale since Thursday, November 30, 2017.This item is in the category "Business & Industrial\Industrial Automation & Motion Controls\Drives & Starters\Starters\Reduced Voltage/Soft Starters". The seller is "ochoapartsautomation" and is located in Toms River, New Jersey. This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Australia, Greece, Portugal, Cyprus, Slovenia, Japan, China, Sweden, South Korea, Indonesia, Taiwan, South africa, Thailand, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Bahamas, Israel, Mexico, New Zealand, Philippines, Singapore, Switzerland, Norway, Saudi arabia, United arab emirates, Qatar, Kuwait, Bahrain, Croatia, Malaysia, Brazil, Chile, Colombia, Costa rica, Panama, Trinidad and tobago, Guatemala, Honduras, Jamaica, Antigua and barbuda, Aruba, Belize, Dominica, Grenada, Saint kitts and nevis, Saint lucia, Turks and caicos islands, Barbados, Bangladesh, Bermuda, Brunei darussalam, Bolivia, Ecuador, Egypt, French guiana, Guernsey, Gibraltar, Guadeloupe, Iceland, Jersey, Jordan, Cambodia, Cayman islands, Liechtenstein, Sri lanka, Luxembourg, Monaco, Macao, Martinique, Maldives, Nicaragua, Oman, Peru, Pakistan, Paraguay, Reunion, Viet nam, Uruguay, Montserrat.