DS7-342SX009N0-N 134928 EATON ELECTRIC Soft starter, 9 A, 200 480 V AC. 321106 CSA-C22.2 No 14-05 UL 508 UL File No. E251034 GB 14048.6 CSA File No.
2511305 CSA-C22.2 No 0-M91 UL CE CSA22.2-14 IEC/EN 60947-4-2 CSA. Internal bypass contacts Internal bypass. Ramp time 1 s - fast switching (semiconductor contactor) Potential isolation between power and control sections Suppression of DC components for motors Suppression of closing transients Single direction Soft start function. Soft starter for three-phase loads. 8 g, 11 ms, Mechanical. Above 1000 m with 1 % derating per 100 m Max.AMBIENT OPERATING TEMPERATURE - MAX. AMBIENT OPERATING TEMPERATURE - MIN. Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-3.
AC-53a: 3 - 5: 75 - 10. RATED OPERATIONAL CURRENT (IE) AT AC-53. RATED OPERATIONAL VOLTAGE (UE) - MAX. RATED OPERATIONAL VOLTAGE (UE) - MIN. PKM0-10 (+ CL-PKZ0), Type "1" coordination, Main conducting paths 3 x 170M1362, Type "2" coordination (additional with the fuses for coordination type "1"), Main conducting paths.
50/60 Hz, fLN, Main circuit. ASSIGNED MOTOR POWER AT 200/208 V, 60 HZ, 3-PHASE.
ASSIGNED MOTOR POWER AT 220/230 V, 60 HZ, 3-PHASE. ASSIGNED MOTOR POWER AT 460/480 V, 60 HZ, 3-PHASE. RATED OPERATIONAL POWER AT 220/230 V, 50 HZ. RATED OPERATIONAL POWER AT 400 V, 50 HZ. TERMINAL CAPACITY (FLEXIBLE WITH FERRULE).1 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 2.5) mm², Main cables 2 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Main cables. 1 x (0.75 - 4) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 4) mm², Main cables 2 x (0.75 - 2.5) mm², Main cables.
18 - 10, Main cables 18 - 10, Control circuit cables. PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver 0.6 x 5.5 mm/1 x 6 mm, Terminal screws, Control circuit cables. 1.2 Nm 1.2 Nm, Screw terminals, Control circuit cables. 1.6 mA, Control circuit, Digital inputs, External 24 V 50 mA, Control circuit, Regulator supply. 350 ms, Control circuit, Digital Inputs, AC operated.
AC operated: 0 - 15 V, AC operated. RATED CONTROL SUPPLY VOLTAGE (US) AT AC, 50 HZ - MIN. RATED CONTROL SUPPLY VOLTAGE (US) AT AC, 50 HZ - MAX. RATED CONTROL SUPPLY VOLTAGE (US) AT AC, 60 HZ - MAX.RATED CONTROL SUPPLY VOLTAGE (US) AT AC, 60 HZ - MIN. RATED CONTROL SUPPLY VOLTAGE (US) AT DC - MAX. RATED CONTROL SUPPLY VOLTAGE (US) AT DC - MIN. 4 mA (at 230 V AC, Digital inputs). 110 - 230 V AC.
Finger and back-of-hand proof, Protection against direct contact. 110 - 230 V AC (-15 %/+10 %) 110 - 230 V AC. RATED OPERATIONAL CURRENT (IE) AT AC-11. 1-phase motors: No 3-phase motors: Yes Soft starting of three-phase asynchronous motors.
0 - 30 s, Soft start function, Ramp times. 30 %, Soft start function, Start voltage = turn-off voltage Max. 100 %, Soft start function, Start voltage = turn-off voltage. EQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT PVID.
HEAT DISSIPATION PER POLE, CURRENT-DEPENDENT PVID. RATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN). STATIC HEAT DISSIPATION, NON-CURRENT-DEPENDENT PVS.
10.2.2 CORROSION RESISTANCE. Meets the product standard's requirements. 10.2.3.1 VERIFICATION OF THERMAL STABILITY OF ENCLOSURES. 10.2.3.2 VERIFICATION OF RESISTANCE OF INSULATING MATERIALS TO NORMAL HEAT.
10.2.3.3 RESIST. TO ABNORMAL HEAT/FIRE BY INTERNAL ELECT. 10.2.4 RESISTANCE TO ULTRA-VIOLET (UV) RADIATION. Does not apply, since the entire switchgear needs to be evaluated.10.2.6 MECHANICAL IMPACT. 10.3 DEGREE OF PROTECTION OF ASSEMBLIES.
10.4 CLEARANCES AND CREEPAGE DISTANCES. 10.5 PROTECTION AGAINST ELECTRIC SHOCK.
10.6 INCORPORATION OF SWITCHING DEVICES AND COMPONENTS. 10.7 INTERNAL ELECTRICAL CIRCUITS AND CONNECTIONS. Is the panel builder's responsibility.
10.8 CONNECTIONS FOR EXTERNAL CONDUCTORS. 10.9.2 POWER-FREQUENCY ELECTRIC STRENGTH.
10.9.3 IMPULSE WITHSTAND VOLTAGE. 10.9.4 TESTING OF ENCLOSURES MADE OF INSULATING MATERIAL.
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. The specifications for the switchgear must be observed.
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. This item is in the category "Business, Office & Industrial\Electrical Equipment & Supplies\Circuit Breakers & Disconnectors\Circuit Breakers".olgc46v" and is located in this country: GB. This item can be shipped to United Kingdom.