Evaluation of thermistor motor protection. Product component Motor brake output.
To DIN 40719 extended according to IEC 204-2 acc. At 40 °C rated value. At 50 °C rated value. At 60 °C rated value. Mechanical power output for three-phase motors. At standard circuit at 40 °C rated value.Yielded mechanical performance [hp] for three-phase AC motor at 200/208 V at standard circuit at 50 °C rated value. Relative negative tolerance of the operating frequency. Relative positive tolerance of the operating frequency. Operating voltage at standard circuit rated value.
Relative negative tolerance of the operating voltage at standard circuit. Relative positive tolerance of the operating voltage at standard circuit. Adjustable motor current for motor overload protection minimum rated value. Continuous operating current [% of Ie] at 40 °C.Power loss [W] at operating current at 40 °C during operation typical. Type of voltage of the control supply voltage.
Control supply voltage frequency 1 rated value. Control supply voltage frequency 2 rated value. Relative negative tolerance of the control supply voltage frequency.
Relative positive tolerance of the control supply voltage frequency. Control supply voltage 1 at AC at 50 Hz. Control supply voltage 1 at AC at 60 Hz.
Relative negative tolerance of the control supply voltage at AC at 50 Hz. Relative positive tolerance of the control supply voltage at AC at 50 Hz.Relative negative tolerance of the control supply voltage at AC at 60 Hz. Relative positive tolerance of the control supply voltage at AC at 60 Hz. Control supply voltage 1 at DC. Relative negative tolerance of the control supply voltage at DC. Relative positive tolerance of the control supply voltage at DC.
Display version for fault signal. Size of engine control device. With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t. Required spacing with side-by-side mounting.
Number of poles for main current circuit. For auxiliary and control current circuit. Number of NC contacts for auxiliary contacts. Number of NO contacts for auxiliary contacts. Number of CO contacts for auxiliary contacts.Type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point. Finely stranded with core end processing. Type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point. Type of connectable conductor cross-sections for main contacts for box terminal using both clamping points.
Type of connectable conductor cross-sections at AWG conductors for main contacts for box terminal. Using the back clamping point. Using the front clamping point.
Type of connectable conductor cross-sections for auxiliary contacts. Type of connectable conductor cross-sections at AWG conductors. For auxiliary contacts finely stranded with core end processing. Installation altitude at height above sea level. 2K2, 2C1, 2S1, 2M2 max. Fall height 0.3 m. 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4. 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6. The item "3RW4036-1BB14 SIRIUS soft starter S2 45A 200-480 V AC screw 3RW40361BB14" is in sale since Tuesday, September 15, 2020. This item is in the category "Business & Industrial\Industrial Automation & Motion Controls\Drives & Starters\Starters\Reduced Voltage/Soft Starters". The seller is "dismartsys" and is located in Moscow. This item can be shipped worldwide.